1500V String Solutions

String inverters 1500 performance

1500v string solutions

Our NEW 3PH string inverters 1500 have been specifically designed for distributed configurations of Utility and large scale PV Plants both indoor and outdoor (IP 65). Thanks to flexible installation and to wide operating voltage range (675/850-1.450 VDC) the new inverters are easily configured with any type of solar panel and installation, also 1.500V.

They are characterized by a complete range of accessories which makes them extremely complete and they don’t require further options which affect often lead to increased costs.

They include in fact the communication port for remote monitoring. The combiner box is separable for maximum flexibility in the installations.

string table

string map

1 PROCTION DEGREE

PROCTION DEGREE

It indicates the classifi cation of the degree of protection provided by mechanical enclosures and electrical boards against the intrusion of solid particles (for example parts of the body and dust) and access of liquids.


2 CE MARKETING

CE MARKING

The product complies with the safety requirements of the applicable EC directives.


3 LVFRT

LVFRT

It is the capability of the inverter to remain connected to the grid even following any poly-phase failure and whenever a voltage dip occurs, within some limits of time.
The curve is completely configurable in order to meet any requirement of the grid code.


4 OVER FREQUENCY REDUCTION

OVER FREQUENCY P REDUCTION

It is the capability of the inverter to reduce the active power P for transient over-frequency of the grid and consequently to participate to Primary Frequency regulation at the POI.
The curve is completely configurable in order to meet any requirement of the grid code.


5 SEMICIRCULAR CAPABILITY

SEMICIRCULAR CAPABILITY

It is the capability of the inverter to able of generating, upon request, a certain amount of active and reactive power in whichever point of the P-Q space delimited by the semi-circular diagram.


6 GRID VOLTAGE REGULATION

GRID VOLTAGE REGULATION FUNCTION BY MEANS OF REACTIVE POWER

Grid voltage regulation function is carried out by appropriate generation of reactive power Q by the Inverter in local logic. The curve is completely confi gurable in order to meet any requirement of the grid code.


7 POWER FACTOR FUNCTION

POWER FACTOR FUNCTION OF ACTIVE POWER

It is the capability of the inverter to regulate in local logic and the power factor at the POI as a function of the active power P. The curve is completely confi gurable in order to meet any requirement of the grid code.